1. Used Industrial Testers & Calibrators Offers
  2. sku: 513529490151604
  3. NIST SRM-2515

SRM-2515 NIST Wavelength Calibration Carbon Monoxide Lines

SRM-2515 NIST Wavelength Calibration Carbon Monoxide Lines
Item Aspects
BrandNIST
Manufacturer Part NumberSRM-2515
Part TypeLINE
Unit TypeUNIT
Country/region Of ManufactureUNITED STATES

Review NIST Wavelength Calibration Reference 1595-1630nm Carbon Monoxide Lines

The NIST SRM 2515 Wavelength Calibration for Carbon Monoxide Lines (1595-1630 nm) is a crucial tool for researchers, scientists, and laboratories that require high-precision and accuracy in their spectroscopic measurements of carbon monoxide (CO) gas. This standard reference material (SRM) is supplied by the National Institute of Standards and Technology (NIST), a renowned institution known for its rigorous standards and metrology expertise.

The NIST SRM 2515 is specifically designed to provide a reliable and traceable calibration source for the CO lines located within the 1595-1630 nm spectral region. These lines are essential for various applications, including atmospheric research, combustion studies, and industrial process control.

The SRM consists of a high-purity CO gas sample that has been carefully prepared and stored under controlled conditions to ensure its stability and consistency. The CO gas is contained within a specially engineered glass bulb, which is sealed and equipped with a leak-tight valve. This design ensures the long-term integrity of the gas sample and minimizes the risk of contamination.

To enable precise wavelength calibration, the NIST SRM 2515 features a calibrated absorption cell with a known path length. The cell is constructed from high-quality, optical-grade materials to minimize absorption losses and ensure accurate and consistent measurements. The cell is also designed to be temperature-controlled, ensuring that the CO gas maintains a stable and consistent temperature during use.

The NIST SRM 2515 comes with a comprehensive certificate of analysis, which includes detailed information on the CO gas concentration, calibration coefficients, and uncertainty estimates. This information is crucial for users seeking to trace their measurements back to a recognized and reputable standard.

In summary, the NIST SRM 2515 Wavelength Calibration for Carbon Monoxide Lines (1595-1630 nm) is an essential tool for laboratories and researchers that demand high-precision and accuracy in their CO gas measurements. With its high-purity CO gas sample, calibrated absorption cell, and comprehensive certificate of analysis, this SRM offers a reliable and traceable calibration source for the 1595-1630 nm spectral region.

Buying NIST SRM 2515 wavelength calibration standards for carbon monoxide lines in the 1595-1630nm range can offer several benefits and drawbacks for researchers and scientists working in fields such as spectroscopy, environmental monitoring, and atmospheric science. Here, we will discuss the pros and cons of purchasing these standards.

Pros:

1. High Accuracy: NIST SRM 2515 is a traceable standard, meaning it comes with a certified calibration report from the National Institute of Standards and Technology. This ensures that the wavelength calibration provided is of the highest accuracy.

2. Improved Measurement Precision: Using a traceable standard like NIST SRM 2515 can help improve the precision of your measurements. By ensuring that your instrument's wavelength calibration is accurate, you can reduce the uncertainty in your measurement results.

3. Compliance with Regulations: In certain industries, such as environmental monitoring, compliance with regulations is essential. Using a traceable standard like NIST SRM 2515 can help ensure that your measurements meet the required accuracy and precision standards.

4. Consistency: Using a traceable standard can help ensure that your measurements are consistent over time. This is important for long-term research projects or for monitoring changes in a system over an extended period.

Cons:

1. Cost: NIST SRM 2515 is a high-precision, traceable standard, and as such, it comes with a higher price tag compared to other calibration sources.

2. Handling and Storage: NIST SRM 2515 is a glass bulb filled with a gas mixture. It requires careful handling and storage to maintain the calibration accuracy. This can add to the overall cost and complexity of using these standards.

3. Limited Lifetime: The calibration provided by NIST SRM 2515 is only valid for a certain period. The standard's calibration certificate will specify the validity period, after which it will need to be recalibrated or replaced to maintain accuracy.

Conclusion:

NIST SRM 2515 wavelength calibration standards for carbon monoxide lines in the 1595-1630nm range offer several benefits, including high accuracy, improved measurement precision, compliance with regulations, and consistency. However, they also come with some drawbacks, such as cost, handling and storage requirements, and a limited lifetime. Ultimately, the decision to purchase NIST SRM 2515 depends on the specific needs and resources of your research or monitoring project. If the benefits outweigh the drawbacks and accurate wavelength calibration is essential to your work, then purchasing NIST SRM 2515 may be a worthwhile investment.

Recommendation:

If you require accurate wavelength calibration for your research or monitoring project and the benefits of using NIST SRM 2515 outweigh the drawbacks, then it is recommended that you consider purchasing this standard. Ensure that you follow the handling and storage instructions provided by NIST to maintain the calibration accuracy and validity of the standard. Additionally, consider budgeting for the cost of recalibration or replacement when the standard's calibration certificate expires.

Details:

Key features and purpose: wave length range: 1595 nm to 1630. Material: 13c16o gas at 133 KP 1000 tore pressure. In excellent shape. Used see photos.

Application: calibrating instruments like unable diode lasers, optical spectrum analyzers, and other equipment, according to the Nist. Nist SRM-2515 wave length calibration reference 1595-1630nm carbon monoxide atomic absorption lines. Cell length : 80 cm path length . Its used in manufacturing and testing to calibrate equipment like unable lasers optical spectrum analyzers.

Connection: fiber-coupled with FCC/PC connectors for input and output.

specifications busitestercalib:

  • brand: Nist
  • mpn: Srm-2515
  • part type: Line
  • unit type: Unit
  • country/region of manufacture: United States

offer busitestercalib:

  • in stock #: 1
  • price: $4949.00
  • item condition: Used
  • started: august 21, 2025
  • options: ship-to-home
  • availability: in stock
  • sold #: 16
  • best offers: true

payments busitestercalib:

  • other
  • credit card: diners-club
  • wallet: google-pay

general busitestercalib:

  • category: Business & Industrial > Test, Measurement Inspection > Testers Calibrators

seller busitestercalib:

  • city: fargo, north dakota
  • # reviews: 1811
  • rating: 99.2%

returns busitestercalib:

  • paid by: buyer
  • method: money back
  • policy: returns accepted
  • time: 30 days

shipping busitestercalib:

  • type: fixed
  • class: standard
  • service: standard
  • transit: 2-6 days
rating: 99.2% out of 100 based on 811 user ratings.
Similar Items:
  • Model: srm 2514.: calibration. Nist srm 2514 calibration: item: make. The unit contains a 20 cm long brisket glass cell filled to a, pressure of 133 KP 1000 tore with high purity 99.95 % 12C16O gas. From 1560 nm to 1595...(January 27th, 2024)
  • Nist SRM-2517A high resolution wave length calibration reference standard 1510-1540NM acetylene atomic absorption lines. FCC/PC connectors. Key feature: the use of lower acetylene pressure compared to srm 2517 results in narrower absorption lines, enabling higher resolution and accuracy wave length...(July 14th, 2025)
busitestercalib logo
1 offer $4949.00 USD
  • Used. USA Seller
© busitestercalib.com